Single, dual and triple outputs
Input: 100/117/220/230-240 VAC or 240/480 VAC
Rated full load at 50°C
Overload and short circuit protection
Remote sense compensates for line drop and assures voltage at the load
Reverse polarity protection
Overvoltage protection (OVP) standard on 5V main outputs
Open sense lead protection
Designed to meet domestic and international safety standards ... View full description
Web address: http://www.powervolt.com Address: 300 Factory Road, Addison, Illinois, United States
Phone: 001-630-628 9999 - Fax: 001-630-628 9922
Detailed Product Description
Single, dual and triple outputs
Input: 100/117/220/230-240 VAC or 240/480 VAC
Rated full load at 50°C
Overload and short circuit protection
Remote sense compensates for line drop and assures voltage at the load
Reverse polarity protection
Overvoltage protection (OVP) standard on 5V main outputs
Open sense lead protection
Designed to meet domestic and international safety standards
2 year warranty
The International Series BVA
The BVA series is the premium grade, open frame line of linear DC power supplies. Designed to operate over a wide range of AC power sources found worldwide, the BVA series is especially suited to OEM applications where cost savings is a significant factor. The field selectable universal input (100/117/220/230-240 VAC) reduces your inventory cost by allowing you to use just one standard model regardless of destination.
Value Added Services
PowerVolt offers a wide variety of value added services and design features to meet your application requirements. The first and foremost service we offer is our flexibility to design custom units for your application. Other features include, but are not limited to, terminal blocks, mounting spacers, fuse and fuse holders, line cords, etc.
Specifications
AC Input: Standard models: field selectable taps for 100/117/220/230-240 VAC ±10%; 47-63 Hz. For 50 Hz operation derate output by 10%.
"480" models: 240/480 VAC ±10%; 47-63 Hz.
DC Output: See Selection guide for voltage / current ratings. The output is floating; either positive or negative terminal can be grounded. Output range is ±10%, except variable 10-18V outputs.
Line Regulation: ±0.05% for 10% line change
Load Regulation: ±0.05% for 50% load change
Thermal Regulation: ±0.02% per °C maximum, ±0.005% per °C typical
Output Ripple: 2 mV RMS maximum, 3 mV P-P
Dynamic Response: 30 µS for 50% load change
Stability: ±0.3% for 24 hour period after 1 hour warm-up
Short Circuit and Overload Protection:
Foldback current limiting, set at 120% of nominal
Overvoltage Protection:
Crowbar overvoltage protection is standard on all 5VDC main outputs and is factory set at 6.2V±0.4V (fixed). Optional OVP module adjustable from 4.5 to 36V is available for other models.
Remote Sensing: Standard on all models above 30 watts. Remote sensing will compensate for a cable drop of 0.25V. Protected against open or shorted sense leads. Twisted pair sense leads are recomended.
Efficiency: 5V units: 45%; 12 and 15V units: 55%; 24V and higher units: 60%
Operating Temperature: 0°C to 50°C full rated load, derate linearly to 40% at 70°C. See derating chart.
Storage Temperature: -55°C to +85°C
Vibration: Per MIL-STD-810B, Method 514, Procedure 1, Curve AB (to 50 Hz)
Shock: Per MIL-STD-810B, Method 516, Procedure V
Safety Standards: Designed to meet safety regulations of UL, CSA and other international standard
Finish: Clear aluminum chassis. Chassis also serves as heat sink.
See More Item(s) from This Company
Isolation transformer
Step-up or step-down isolation transformer
Field selectable taps allow many possible voltage ratings
Industry grade, conservative and reliable design
2500V r.m.s. hipot is standard
Dual...
Microprocessor power transformer
Transformer for triple output power supplies used in microprocessor, Op-amp and other logic circuits
Printed circuit or panel mount
Low profile or small mounting surface models
Class B...
Class2 Transformer
Power Rating 25VA to 80VA
Dielectric strength - 4000VRMS
Primaries - Dual primaries (115/230V - 50/60Hz)
Secondaries - Single secondaries
Class 2 Rating - Inherently or non-inherently limited...
Triple output Power Transformer 25VA-80VA
Power Rating 25VA to 80VA
Dielectric strength - 4000VRMS
Primaries - Dual primaries (115/230V - 50/60Hz)
Input range (100V to 130V to 260V - 50/60Hz)
Secondaries - Dual complementary output...
Power Transformer 25VA -175VA
Power Rating 25VA to 175VA
Dielectric strength - 4000VRMS
Single or Dual primaries (115/230V - 50/60Hz)
Series or Parallel secondaries
Electrosatic Shield - Not required, dual bobbin
Solder...
Power Transformer
Panel mounting
Printed circuit mounting
International Series
Custom designs
2 Year warranty
Unregulated Open Frame DC Power Supplies
Low cost unregulated DC power supplies
Field selectable input taps 103/115/126/207/230/253 VAC for fine-tuning output to match actual field conditions
Improved ripple - 3% maximum
Fuse...
Three phase open frame DC power supply
Unregulated DC output
480V, 3-phase input eliminates need for step-down transformer
Field selectable 430/460/480/500/530V input tap
Finger-safe and creepage-proof screw terminal...
Stepper power for stepping motor
Full compatible with Pacific Scientific (and other) stepping motor
driver sreies 5200, 5300, 5400, 6400
Space saving compact modules provide mounting studs for motor drivers
Integral motor and...
Switch mode power supply
Single and Multiple outputs, 30 to 180 watts
Worldwide AC input range 90 to 264 VAC
Choice of tightly regulated, high peak current auxiliary outputs
Extremely versatile output configuration for...