Single and Multiple outputs, 30 to 180 watts
Worldwide AC input range 90 to 264 VAC
Choice of tightly regulated, high peak current auxiliary outputs
Extremely versatile output configuration for a variety of applications
Superior light losd operation without audible noise
Power fail/logic inhibit signal on 80W
DC "OK" and remote sense signal on 180W units
UL, CSA, recognized and CE marked
4-hour burn-in ... View full description
Web address: http://www.powervolt.com Address: 300 Factory Road, Addison, Illinois, United States
Phone: 001-630-628 9999 - Fax: 001-630-628 9922
Detailed Product Description
Single and Multiple outputs, 30 to 180 watts
Worldwide AC input range 90 to 264 VAC
Choice of tightly regulated, high peak current auxiliary outputs
Extremely versatile output configuration for a variety of applications
Superior light losd operation without audible noise
Power fail/logic inhibit signal on 80W
DC "OK" and remote sense signal on 180W units
UL, CSA, recognized and CE marked
4-hour burn-in
2-year warranty
General Specifications
AC Input:
BVS products automatically adjust to the input voltage as follows: BVS30, 40, 60 and 80: wide range input from 90-264 VAC
DC Outputs
Peak Output Power:
See Voltage/Current Rating Charts.(Standard Models)
Sixty second maximum peak power durations. A 10% duty cycle is not to be exceeded when peak power durations are combined.
Brown-Out Voltage:
Regulation is maintained with full rated load at 90 VAC
Hold-Up Time:
20 msec typical at full rated load and nominal AC input voltage. Hold-up time increases to 40 msec at 50% load.
Power-Fail Warning Signal:
TTL compatible signal goes low before the main +5V output drops 5%, at full rated load on BVS 80 Typical warning time:
BVS 80: 5 msec where applicable
Warning time increases at reduced load levels
Efficiency:
Measured at full rated load and nominal AC input voltage. 75% ±5% depending on how the load is distributed among the outputs.
Measurement method:
Line: Measured over a 90-132 VAC or 175-264 VAC line change.
Load: Measured over a 20% to 100% load change. Multiple output model regulation is subject to the minimum load
requirements mentioned below.
Minimum Loads:
The following minimum loads are required to maintain regulation. Multiple output models are expressed as current on the main output. Multiple output Single output Multiple Output Single Output
BVS 80 1A 5 Watts
BVS 40, 60 0.5A 3 Watts
BVS40 board only models: Consult factory for minimum load requirements. Please note those minimum load requirements increase at temperatures over 50°C.
Initial Setting Tolerance:
Measured at 50% of full rated load on all outputs.
Remote Sensing:
Optional on selected models only.
Output Noise and Ripple:
0.3% RMS, 1% PK-PK maximum on main +5V output.
Transient Response:
Main +5V output: 500 sec typical for a 50-100% load change and recovery to within 1% of initial voltage set point. Maximum excursion: 4% from initial voltage set point.
Overload Protection:
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition. Delayed-foldback current limiting characteristics assure reliable turn-on into reactive and non-linear loads.
Overvoltage Protection:
Provided on the main +5V output. Factory set at 6.2V±0.6V.
Overvoltage Protection:
Provided on the main +5V output. Factory set at 6.2V±0.6V.
See More Item(s) from This Company
Isolation transformer
Step-up or step-down isolation transformer
Field selectable taps allow many possible voltage ratings
Industry grade, conservative and reliable design
2500V r.m.s. hipot is standard
Dual...
Microprocessor power transformer
Transformer for triple output power supplies used in microprocessor, Op-amp and other logic circuits
Printed circuit or panel mount
Low profile or small mounting surface models
Class B...
Class2 Transformer
Power Rating 25VA to 80VA
Dielectric strength - 4000VRMS
Primaries - Dual primaries (115/230V - 50/60Hz)
Secondaries - Single secondaries
Class 2 Rating - Inherently or non-inherently limited...
Triple output Power Transformer 25VA-80VA
Power Rating 25VA to 80VA
Dielectric strength - 4000VRMS
Primaries - Dual primaries (115/230V - 50/60Hz)
Input range (100V to 130V to 260V - 50/60Hz)
Secondaries - Dual complementary output...
Power Transformer 25VA -175VA
Power Rating 25VA to 175VA
Dielectric strength - 4000VRMS
Single or Dual primaries (115/230V - 50/60Hz)
Series or Parallel secondaries
Electrosatic Shield - Not required, dual bobbin
Solder...
Power Transformer
Panel mounting
Printed circuit mounting
International Series
Custom designs
2 Year warranty
Unregulated Open Frame DC Power Supplies
Low cost unregulated DC power supplies
Field selectable input taps 103/115/126/207/230/253 VAC for fine-tuning output to match actual field conditions
Improved ripple - 3% maximum
Fuse...
Three phase open frame DC power supply
Unregulated DC output
480V, 3-phase input eliminates need for step-down transformer
Field selectable 430/460/480/500/530V input tap
Finger-safe and creepage-proof screw terminal...
Stepper power for stepping motor
Full compatible with Pacific Scientific (and other) stepping motor
driver sreies 5200, 5300, 5400, 6400
Space saving compact modules provide mounting studs for motor drivers
Integral motor and...
Linear Power Supply
Single, dual and triple outputs
Input: 100/117/220/230-240 VAC or 240/480 VAC
Rated full load at 50°C
Overload and short circuit protection
Remote sense compensates for line drop and assures...