Bikudo

HCl gas filled in 500kg/drum chemicals gases of hydrochloric acid (hcl)

HCl gas filled in 500kg/drum chemicals gases of hydrochloric acid (hcl)
Supplier:
Manufacturer
708, NO.9, NO.818, LINZI AVENUE, ZIBO CITY, SHANDONG PROVINCE, CHINA
FOB price:1-199 Kilograms
$2.50
200-499 Kilograms
$2.30
>=500 Kilograms
$2.10
Min. order:1set
Origin:China
Brand name:Dijia
Color:colorless
Lead time:20-40days
Port:tainjin

Description

Quick Details
Classification:Hydrochloric Acid
CAS No.:7647-01-0
Other Names: muriatic acid
MF:HCL
EINECS No.:231-595-7
Place of Origin:Shandong, China (Mainland)
Grade Standard:Agriculture Grade, Food Grade, Medicine Grade, Reagent Grade
Purity:99.9
Appearance:gases
Application:dye
Brand Name:yanhe
Model Number:lc-054
Packaging Details:cylinders
Color:colorless
UN NO:1050
Usage:industrial
Size:44L
Experiences:29 years
Quality:Prime
Form:gas
Certificate:SGS MSDS COA
HS Code:2806100000

Packaging & Delivery
Selling Units:
Single item
Single package size: 
11X11X11 cm
Single gross weight:
79.0 kg
Package Type:
GAS CYLINDER
Lead Time :
Quantity(Set) 1 - 1 2 - 20 21 - 50 >50
Est. Time(days) 20 30 45 To be negotiated



parameter
Hydrogen Chloride Physical Constant
 
Molecular Formula : HCL Molar Volume : 22.25L
Molecular Weight : 36.46 Gas Viscosity Measurement  (20℃) : 1.56c/o 10-5Pa S
Gas Specific Weight   (0℃, Air=1) : 1.268 Constant-pressure Specific Heat(15℃,0.1MPa) : Cp=0.812Kj/Kg K
Specific Gravity Hydrometer(10℃, Water=1) : 0.88 Constant-volume Specific Heat(15℃,0.1MPa) : Cv=0.576Kj/Kg K
Critical Pressure : 8.258MPa 1L Liquid(10℃)= 540L Gas
Critical Temperature : 51.4℃ 1Kg Liquid= 613L Gas
Critical Density : 0.424g/cm3 Latent Heat Of Melting : 54.80Kj/Kg
Latent heat Of Evaporation : 443.3Kj/Kg Atmospheric Boiling Point : -85℃
Gas Density(0℃,0.1MPa) : 1.639g/dm3  (21℃,0.1MPa) : 1.522g/dm3
 
Liquid hydrogen chloride vapor pressure:
Temperature (℃) -85.03 -10 0 10 20 30 40
Pressure (Mpa) 0.1 1.96 2.57 3.32 4.21 5.27 6.53
Density (g/cm3) 1.191 0.962 0.924 0.881 0.831 0.772 0.697


Physical & Chemical Properties
 
Colorless, toxic, irritating, smothering, non-flammable gas: strong hygroscopic, after absorbing the moisture in the air, hydrochloric acid is generated, with strong corrosiveness.
Stored in cylinders in the form of liquefied gas, pressure (3-6MPa) is constant, and its value is related to temperature.Inorganic compounds such as tin chloride, phosphorus trioxide, phosphorus bromide, and so on, and organic compounds such as paraffin, ethanol, ether, acetaldehyde, ketone, acid, ester, nitrite, cyano, etc. can be dissolved well in hydrogen chloride, and additional reaction can occur.
Pure liquid hydrogen chloride does not react with most metals. However, it reacts with alkali metals, aluminum, manganese, iron, copper, tin, lead and zinc and produces a protective film of chloride on its surface. When water is present, it reacts with metal to form metal chloride and hydrogen gas.

HAZARDS IDENTIFICATION
Classification of the substance or mixture
Gas under Pressure (Liquefied gas).
Acute toxicity(inhalation) Category 3
Skin corrosion/irritation Category 1A



GHS Label elements, including precautionary statements
Signal word: Danger

Hazard statement(s): Contains gas under pressure; may explode if heated. Toxic if inhaled. Causes severe skin burns and eye damage.

Precautionary statement(s):

Prevention: Avoid breathing dust/fume/gas/mist/ vapors/spray. Use only outdoors or in a well-ventilated area. Wash thoroughly after handling. Wear protective gloves/protective clothing/eye protection/face protection.

Response: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting. IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor. Specific treatment (see next). IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. Wash contaminated clothing before reuse. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor.

Storage:Protect from sunlight. Store in well-ventilated place. Keep container tightly closed. Store locked up.

Disposal: Dispose of contents/container to relevant regulations.


Description of necessary first aid measures
If inhaled: If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

In case of skin contact: Wash off with soap and plenty of water.

In case of eye contact: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.

If swallowed: Not considered a normal route of entry.



Use & Storage
 
The storage room for hydrogen chloride cylinder should be ventilated and dry, avoid direct sunlight, and there should be no underground trenches or secret passages. Open fire is strictly forbidden and away from heat source.
Cylinder should be placed vertically, with the cap, properly fixed, prevent dumping.
When using, connect the exhaust nozzle of the cylinder valve with the production device. Gas leakage is strictly prohibited.
When used, the ambient temperature is between -20 degrees Celsius and 40 degrees Celsius
Avoid sun exposure and stay at least 10 meters away from an open flame.
The gas in the bottle shall not be used up, and the pressure shall be kept at not less than 0.5mpa.
For the intermittent system, the air of the high-purity nitrogen replacement system should be used first, and then the hydrogen chloride should be used to enter the system and discharge nitrogen, so that the system can carry out normal production. After production, hydrogen chloride in the high purity nitrogen replacement system is used to prevent system corrosion. After use, close the cylinder valve in time, remove the cylinder from the system, wipe each part of the cylinder valve, and tighten the bottle cap.
The use of self - contained cylinders, the valves must be changed by us. If the bottle valve is damaged, please ask our company to replace it.
Special cylinder for hydrogen chloride is strictly prohibited to refit other gases.
Cylinder body and valve are strictly prohibited oil pollution.
In the process of use, when the gas cylinder exhaust speed is relatively fast, the cylinder and pipeline crystallization is normal, and it is forbidden to be poured with hot water. In order to avoid frost in cylinder and pipeline, please use special gas supply device when the flow rate of gas consumption is greater than 2m3/h. We can provide special air supply equipment.
When the reliability of the cylinder cannot be determined, it should be tested immediately. The cylinder safety inspection period is two years, and the cylinder beyond the safety inspection period cannot be used.
The cylinder should be sent to us for maintenance after one year of use
The user unit shall organize workers and relevant management personnel to study the technical specification of hydrogen chloride safety, and be familiar with the accident hazards that may occur with hydrogen chloride gas and other relevant knowledge and information such as first aid and emergency measures.



Chemical Hydrogen Chloride 2.8N
Level: Chemistry 2.8N
PURITY/%: ≥99.8%
Packing: 40L/44L
Enterprise number: LC054
Weight: 25Kg/27Kg
Pressure: 4.2 Mpa (20℃)
Valve: CGA330- 316LDiaphragm Valve



  Composition Product specification Inspection Equipment Limit
Impurity   1*10-6(v/v) Nitrogen <= 85 Heat Ion Chromatograph 5.00
Oxygen + Argon <=10 Heat Ion Chromatograph 5.00
Hydrocarbon <=1900 Hydrogen flame ionization detector 0.10
Water <=5 Online Micro Water Analyzer 0.10
Dew point/℃   <-66 Photoelectric Dew Point Meter -84

Synthesis of fine chemicals such as pesticide intermediates, dye intermediates, catalysts, chemical auxiliaries and additive




Regulations:

This safety data sheet is in compliance with the following national standards: GB16483-2008, GB13690-2009, GB18218-2009, GB15258-2009, GB6944-2012, GB190-2009, GB191-2009, GB12268-2008, GA57-1993,

GB/T 15098-2008, GBZ 2-2007 as well as the following national regulations: Dangerous Goods Transport Administrative Regulation, Dangerous Chemicals Safety Administrative Regulation.


FAQ:
 
1. What is hydrogen chloride?
The aqueous solution of hydrogen chloride (HCl) is called hydrochloric acid.

2. What are the areas where hydrogen chloride is used?
Battery, medicine, dyestuff, fertilizer, glass processing, metal cleaning, organic synthesis, corrosion photography, pottery manufacturing, food processing, inorganic chloride manufacturing, rubber, catalyst, electronic gas, standard gas, epitaxy, diffusion, oxidation, etching, chemical gas deposition, light-emitting diode, etc.

3. Why choose to cooperate with "Yanhe"?
Focus on the development and manufacture of hydrogen chloride gas for over 29 years, we are the preferred supplier for many dealers.

4. Can I become an agent?
Yes, of course. Details require more communication.
© 2005-2020 Bikudo Privacy PolicyTerms of Service