More and more loads are non-linear, introducing harmonics into the power grid and thus significantly impairing the power quality. NK active harmonic filter apf is an ideal product effectively reduces the unwanted harmonics.

Non-linear loads, by contrast with linear loads, have become increasingly common: frequency converters in drive systems, the large numbers of switch-mode power supplies used in IT and communications equipment, and also more and more in household electronics. Even lighting technology employs mainly non-linear power supplies. Non-linear loads becomes more and more in industrial plants, office buildings, data centers or even private households.

690v Active power filter based on our company many years experience, is a very reliable product. The user can set the parameters so that the active harmonic filter apf can simultaneously filter out harmonics, dynamically compensate reactive power, compensate for three phase unbalance, and compensate for voltage drop, etc.

Features:

Active power filter is a new type of electronic device for dynamic filtering of harmonic wave and reactive power compensation. It can conduct real-time filtering and compensation to harmonic wave (both size and frequency are changed) and dynamic reactive power, and is used to overcome disadvantages of traditional harmonic suppression and reactive compensation methods of traditional filters,thus realizing systematic harmonic filtering function and reactive power compensation function. In addition, it is widely applied into power,metallurgy. petroleum, port, chemical and industrial and mining enterprises.

1. Modular design, any module failure will not affect the normal operation of other modules, greatly improving the reliability of the whole equipment; can achieve smooth expansion of multiple direct parallel operation.The master-slave control mode is used when multiple units are expanded; when multiple modules are connected in parallel, all modules can share a set of current transformers.

2. The odd-order harmonic currents of 2 to 50 times or less can be filtered out at the same time, and the harmonics of the 13 types of filtering can be set as needed.When the load current distortion rate is >20%, not less than 85%; when the load current distortion rate is